Heavy Duty Cleaner
Part No: RXSOL-16-1032-210
Generic Name: Oil Remover
Also known as: Care Clean HD, SEA SHIELD, HEAVY DUTY CLEANER 79104 210 ltr
Heavy Duty Cleaner Emulsifier is a low-foaming solvent emulsifier cleaner used for cleaning marine equipment that is seriously contaminated with fuel or lubricating oils.
Product Description
Heavy Duty Oil Cleaner or Heavy Duty Cleaner Emulsifier is a low-foaming solvent emulsifier cleaner used for cleaning marine equipments and Boiler, Cooling system that is seriously contaminated with fuel or lubricating oils. Product Link https://rxmarine.com/RXSOL-HDC
Technical Specifications
Physical Properties
|
Appearance |
yellow transparent liquid |
|
Odor |
Mild |
|
Specific Gravity at 25° C (77° F) |
0.86 – 0.9 |
|
Flash Point (PMCC) |
65.5° C (150° F) |
|
packing |
25 Ltrs / 210 Ltrs |
Product documents & quotation
Request the current SDS and TDS for Heavy Duty Cleaner (RXSOL-16-1032-210). Include your quantity, application, delivery location and required date. Availability, pack sizes and lead times are confirmed with your quotation.
Request SDS, TDS & quoteSupplier: RXSOL, Dubai, UAE. Brand: RXSOL.
Dosage & Application
- Drain the cooling system and refill with fresh water. With the engine stopped, circulate and heat until the water temperature reaches about 60° C (140° F).
- Add 2% by volume (20 liters/metric ton) Heavy Duty Cleaner (Emulsifier) to the circulating water. Heavy Duty Cleaner (Emulsifier) may be introduced by means of the chemical feed system or added to the expansion tank.
- Circulate water through the system for a minimum of 4 hours.
- After 4 Hours cool to normal draining temperatures. Drain the system and refill with warm water to prevent thermal shock. Recirculate for 1-2 hours. No heating is required during this circulation period. Be sure to overflow the system through the expansion tank to the bilge.
- Drain the cooling water system and wherever possible, inspect the interior. If the system is not completely free of oil, repeat the above procedure.
If medium to heavy rust is present, it can be removed by using treatment or a solution of RXSOL SAFE ACID / DESCALEX POWDER and rock salt. If any sacrificial anodes are present in the system, they must be removed prior to cleaning. After cleaning, the anodes can be replaced.Cleaning Procedure
- Drain the cooling system and refill with fresh water. With the engine stopped, circulate and heat until the water temperature reaches about 60° C (140° F).
- Add 2% by volume (20 liters/metric ton) Heavy Duty Cleaner (Emulsifier) to the circulating water. Heavy Duty Cleaner (Emulsifier) may be introduced by means of the chemical feed system or added to the expansion tank.
- Circulate water through the system for a minimum of 4 hours.
- After 4 Hours cool to normal draining temperatures. Drain the system and refill with warm water to prevent thermal shock. Recirculate for 1-2 hours. No heating is required during this circulation period. Be sure to overflow the system through the expansion tank to the bilge.
- Drain the cooling water system and wherever possible, inspect the interior. If the system is not completely free of oil, repeat the above procedure.
If medium to heavy rust is present, it can be removed by using treatment or a solution of RXSOL SAFE ACID / DESCALEX POWDER and rock salt. If any sacrificial anodes are present in the system, they must be removed prior to cleaning. After cleaning, the anodes can be replaced.
Notes
Features
Splits after cleaning, releasing the oil phase for reclamation. Powerful Emulsifier with quick penetration and good emulsifying properties. The emulsifying agents in this product are biological degradable. Rapid rinsing, leaves clean and oil-free surfaces.
Applications
Oily deposits in steam boilers are a result of oil contamination of the feed water. Most often, the source of the oil is some part of the condensate and return system. Fuel oil and cargo oils may contaminate the condensate via leaks in the oil heaters or tank heating coils. Lubricating oils may be picked up from steam driven machinery. Oil deposits can be removed from boilers, L.P. steam generators, etc., by circulating a 2-5% solution of Heavy Duty Cleaner (Emulsifier) through the equipment. Heavy Duty Cleaner (Emulsifier) should never be used as an on-line cleaner. All cleaning should be done off-line. For maximum cleaning efficiency, the cleaning mixture should be heated to 50° - 60°C (122° - 140° F) and maintained at this temperature during the cleaning operation. If adequate heat is not available, effective cleaning can be accomplished at temperatures as low as 25° C (77° F) using additional time. Carbonized oil or coke may require a two-step cleaning process using FOTTM fuel oil treatment followed by Heavy Duty Cleaner (Emulsifier)
Related Products
Industrial Degreasers and Oilfield Cleaners
Air Cooler Cleaning Chemical LT
Part No: RXSOL-16-1049-025
Also known as: Air Cooler Cleaning Chemical LT 25 Ltr, Air Cooler Cleaner L.Y. Merichem
Solvent emulsion cleaner for cleaning of Air coolers, Scavenging air systems and turbochargers of diesel engine.
View DetailsIndustrial Degreasers and Oilfield Cleaners
Aqua Sol Break Degreaser
Part No: RXSOL-16-3003-020
Also known as: Aqua Sol, AquaBreake PX, AquaBreak 20 Ltr PACK
Concentrated cleaning agent based on nonionic detergents, alkaline components, special components to stabilise the hardness and corrosion inhibitors for aluminium.
View DetailsIndustrial Degreasers and Oilfield Cleaners
Cold Washer HD
Part No: RXSOL-20-2003-210
Also known as: Super Degresol-CP / X' Cell 54, 651 571430, COLDWASH HD, Eazy Degreaser, ColdWash, Cold Wash 210 Ltr
Heavy duty highly concentrated and economical emulsifier. Safe to use on most metal surfaces, painted and coated surfaces and also used as a multipurpose degreaserin extremely hard cleaning conditions.
View DetailsFrequently Asked Questions
How do I order Heavy Duty Cleaner?
Quote the product name and part number RXSOL-16-1032-210, quantity, delivery address and required date. RXSOL will confirm availability, packaging, price and delivery terms before you order.
How can I request the SDS and TDS for Heavy Duty Cleaner?
Use the document request below and include the product name and part number. Ask for the current supplier Safety Data Sheet (SDS), Technical Data Sheet (TDS) and any batch Certificate of Analysis (CoA) required by your procurement team.
How do I confirm suitability for my application?
Check the current product specification against your application, equipment materials and operating conditions. Product grades and formulations differ; use the supplier documentation for the exact product rather than a general category recommendation.