RXSOL logoRXSOL
Back to Oilfield Water Treatment Chemicals
Oilfield Water Treatment Chemicals

Hydro Testing Oxy Scavenger Biocide

Part No: RXSOL-34-4035-210

Generic Name: Oxygen Scavenger and Biocide

Also known as: REMIDOL 4000, Hibitol 2000, Indion 175, Visco 3900, Nevamine, Hydrotesting Corrosion Inhibitor, Visco Nalco 3900, Tretolite WF-166, RX-5255

Hydro-testing corrosion protection for Pipeline, Tank

Pack Size:210.00 Ltr.

Product Description

Hydro Testing Oxy Scavenger Biocide is a multicomponent, multifunctional formulation which prevents corrosion, microbiological growth in single product treatment programme. Inhibitor, corrosion, multicomponent, multifunctional: For prevention of corrosion and microbiological growth in water flood systems during hydrostatic testing and other applications.

Technical Specifications

 
Form                                         Liquid
Colour Colourless to slightly Yellow
Odour Sharp
Flash Point  > 100C
Density 1.05-1.11 g/cm3 (25C)
pH 3 - 7
 

Non-Flammable

Safe Plant Handling
Low Odor
Provides corrosion protection in the liquid and the vapor phase
When used in hydrostatic testing the product provides protection in liquids below, above and at the liquid levels. Protection of recessed and hard to reach areas. Complicated valves and the interior surfaces of piping and equipment, which are often difficult or impossible to reach, are protected with true Vapor Corrosion Inhibitor action. Can be applied for hydrotest solution, metalworking fluids, coatings, adhesives and water treatment formulations.

Product documents & quotation

Request the current SDS and TDS for Hydro Testing Oxy Scavenger Biocide (RXSOL-34-4035-210). Include your quantity, application, delivery location and required date. Availability, pack sizes and lead times are confirmed with your quotation.

Request SDS, TDS & quote

Supplier: RXSOL, Dubai, UAE. Brand: RXSOL.

Dosage & Application

Hydro Testing Oxy Scavenger Biocide can be fed directly or through chemical doses pump. Doses may vary with the quality of water to be treated and the residence time of the water in the system.

Actual consumption is determined under operating conditions.

Available Pack Sizes

Hydro Testing Oxy Scavenger Biocide removes free oxygen radicles and prevents corrosion and microbiological growth in water flood systems during hydrostatic testing and other applications. Available in 20 ltr., 25, 50, 210 ltr.

Notes

Benefit  / Advantage of using Hydro Testing Oxy Scavenger Biocide:

  • Hydro Testing Oxy Scavenger Biocide is a liquid multifunctional chemical designed to completely treat hydrostatic test fluid, saltwater packer fluid, saltwater drilling fluid, during Hydro-testing and oil field water injection programme.
     
  • Hydro Testing Oxy Scavenger Biocide contains an effective filming corrosion inhibitor, oxygen scavenger and biocide, altogether in a single formulation convenient to dose with single chemical injection pump or skid.
     
  • Hydro Testing Oxy Scavenger Biocide is economical to use as handling is limited to one chemical.

Applications

PERFORMANCE:

CORROSION
: Effectively prevents corrosion due to Carbon Dioxide, inorganic salts, dissolved oxygen & Hydrogen sulphide contamination from sour fluid or bacterial action. The inhibitor acts as a cathodic polarizer

MICROBIOLOGICAL GROWTH: Effectively prevents the metabolic function necessary for reproduction of the bacteria cell. Successfully prevents anaerobic/aerobic and sulphate reducing bacteria.

Inhibitor, corrosion, multicomponent, multifunctional: For prevention of corrosion and microbiological growth in water flood systems during hydrostatic testing and other applications

Additional Details

Useful Area

The major factor which contributes to the corrosion in hydro-static test water is the dissolved oxygen and dissolved solids do not have much impact on the corrosion rate except the chloride content. The presumptions like not using the corrosion inhibitor if the water is not with high mineral content could beM disastrous as in fact any corrosion process, even a very mild one, will be accompanied by the set up of galvanic cells and formation of corrosion products deposits. Such environment makes the conditions ideal for the corrosion process to continue at accelerated rate once the process fluid will be run through the line.

Industrial Area

Effect of Micro – Organisms:


All water used for Hydro-testing generally contains iron bacteria and sulphate reducing bacteria. The iron bacteria attack to the pipe wall mostly at 6 o’clock location and produces tubercle of iron oxide by metabolic action. Below the tubercles, sulphate reducing bacteria grows and generates H2S from sulphate of water. The H2S goes on reacting with iron forming Fe2S. This is combined with auto catalytic formation of HCI under tubercle and lead to deep pitting and perforation of the pipe wall. The mechanism is more pronounced under stagnant condition and is relevant of Hydrostatic testing.

Frequently Asked Questions

How do I order Hydro Testing Oxy Scavenger Biocide?

Quote the product name and part number RXSOL-34-4035-210, quantity, delivery address and required date. RXSOL will confirm availability, packaging, price and delivery terms before you order.

How can I request the SDS and TDS for Hydro Testing Oxy Scavenger Biocide?

Use the document request below and include the product name and part number. Ask for the current supplier Safety Data Sheet (SDS), Technical Data Sheet (TDS) and any batch Certificate of Analysis (CoA) required by your procurement team.

How do I confirm suitability for my application?

Check the current product specification against your application, equipment materials and operating conditions. Product grades and formulations differ; use the supplier documentation for the exact product rather than a general category recommendation.

Send an Inquiry