RXSOL Zyme 700 FN
Part No: RXSOL-15-1540-005
Generic Name: Enzyme Sewage Treatment Powder
Also known as: GAMAZYME 700FN, Biotal MDC 2000 / Washing Cream Bactericidal, (Shahran) TDS-111, Gamazyme TDS 5 Kg JAR
Concentrated biologically active powder formulation containing a blend of patented bacterial strains, specifically developed to deal with sewage wastes.
Product Description
RXSOL Zyme 700 FN is a concentrated biologically active powder formulation containing a blend of patented bacterial strains, specifically developed to deal with sewage wastes.
Technical Specifications
|
APPEARANCE |
Tan, saw dust like powder in sealed solupacs |
|
pH, in conc. |
N/A |
|
COMPATIBILITY |
|
|
Metal |
No known effect |
|
Rubber |
No known effect |
|
Synthetic rubber |
No known effect |
Product documents & quotation
Request the current SDS and TDS for RXSOL Zyme 700 FN (RXSOL-15-1540-005). Include your quantity, application, delivery location and required date. Availability, pack sizes and lead times are confirmed with your quotation.
Request SDS, TDS & quoteSupplier: Abu Dhabi Chemicals, Fujairah, UAE. Brand: RXSOL.
Dosage & Application
Sewage treatment plant :
Direct dosing to the sewage treatment plant or via the nearest toilet will greatly enhance the biological activity and keep the plant at peak operating efficiency.
A) On ships except passenger vessels
Ineffective or septic sewage treatment can be reactivated and maintained in peak operating efficiency by dosing Rxsol Zyme 700 FN direct in the tank or via the nearest toilet. To reactivate the plant, 1 kg Rxsol Zyme 700 FN should be mixed with 10-15 litres of hand hot (35°C) fresh water, left for 10-15 minutes (stirring periodically) for the bacteria to activate before dosing into the tank daily until the system is operating efficiently. Maintenance dosing of 0.1 - 0.25 kg weekly will keep the system operating effectively. Replacing the toilet cleaner in use by Rxsol Zyme BTC (biological toilet cleaner) will dose millions of specialised bacteria into the system. These powerful bacteria will digest organic material lining the pipes and boost the bacterial activity in the sewage treatment plant, keeping it operating at peak efficiency.
Passenger vessels
The applications is the same as mentioned above, but the dose rates are different. The dose rate depends on the number of people on board the vessel. As a rule of thumb use 50 gram per m3 of the volume of the sewage tank. Then a weekly dosage of 10 gram per m3 of the volume of the sewage tank.
For cruise vessel with a sewage tank on 100 m3 and 2500 people and on a two weeks cruise dose as below
Initial dosage: (50 g/m3 x 100 m3 ):1000 = 5 kg
Weekly dosage: (10 g/m3 x 100 m3 ):1000 x 2 weeks = 2 kg
On this cruise, will be used. 7 kg of Rxsol Zyme 700 FN
Tank Cleaning
Holding tanks can be cleaned periodically or prior to entry without the use of dangerous toxic chemicals. Grey and black water holding tanks, sewage tanks, sewage treatment plant should be flooded and pumped empty to clear excess soil before cleaning. Holding tanks must be fitted with an air manifold connected to a low pressure air line of sufficient volume to gently turn the mass of water within the tank. In sewage treatment tanks the normal air supply will suffice.
The tank should be filled to 75% capacity with fresh or sea water and the air supply turned on. Approximately 0.5 kg of Rxsol Zyme 700 FN in 5 to 10 litres of fresh hand hot (35°C) water should be mixed and left for 10-15 minutes before dosing into the tank. Dosing can be either direct or via the nearest toilet. The tank should then be filled and left with the air on for at least 48 hours. The dose rate should be approximately 0.5 kg per 500 litres tank capacity with a minimum dose of 5 kg. Although Rxsol Zyme 700 FN formulated for use in cold (15°C minimum) sea water, performance will improve with lukewarm (35°C) fresh water or sea water.
Pipe cleaning
Maintenance dosing will keep galley and sewage pipes clean and clear of organic residual wastes. A liquid solution should be prepared by mixing of 0.5 kg of Rxsol Zyme 700 FN in 15 to 20 litres of hand hot (35°C) fresh water. Stir it and, if possible, leave for 15 minutes to reactivate the bacteria. Whilst constantly agitating this solution, 1 litre should be dosed into sinks, scuppers, showers, drains, waste disposal units, etc. each evening until the blockage is cleared. A maintenance dose once or twice a week can then be applied to keep the pipes in clean condition. Harsh toxic cleaners (acids, caustics, disinfectants) should not be used as these will kill off the bacterial action in the pipes. Alternatively, the pipes should be isolated and filled with the solution and left for up to 48 hours before draining. If necessary, further applications should be made until drains run clear.
Available Pack Sizes
1, 5, 10 Kg JAR PACKING
Notes
NOTE: Severly scaled systems should be acid cleaned.
Features and Benefit :
• Powder formulation for easy use.
• Biodegradable.
• Reactivates biological activity in systems which have been rendered inactive by overloading, washout or use of aggressive cleaning products.
• Eliminates the odours associated with sanitary systems which are overloaded or blocked.
• Cleans sewage holding tanks without the need for manual entry.
• Clears pipes and systems blocked by organic waste matter.
• Clears organic materials in slow draining pipes and scuppers.
• Restarts septic sewage treatment plant.
• Keeps complete sanitary systems in optimum operational condition.
• Eliminates the need for hazardous chemicals.
• Cost-effective, saves time, money and manpower.
Applications
Directions for use :
Rxsol Zyme 700 FN is formulated to degrade excess residual waste products in shipboard sanitation pipe work systems, holding tanks and marine sewage treatment plants. The specialised strains in Rxsol Zyme 700 FN will digest grease, fats, sewage, starch and other organic compounds. The degradation of paper, protein and waste product residuals is greatly increased, and the odours that these produce, are reduced.
The bacteria in Rxsol Zyme 700 FN will colonise the waste organic material which lines the pipework/tank system and degrade the waste until the system is clean. The biological activity in the marine sewage treatment plant is greatly increased, so the plant can thus handle more waste. The obnoxious smells in toilet areas and scuppers, normally associated with overloaded or blocked systems, are reduced.
Related Products
Oilfield Water Treatment Chemicals
Chlorine Liq
Part No: RXSOL-31-3034-050
Also known as: Chlor 12 , CLF-35 Chlorination, purollux
12-15 percent free Chlorine Solution for Sterilization of waterClear greenish-yellow liquid miscible in any proportion with water.
View DetailsOilfield Water Treatment Chemicals
Condensor Dispersant Scale Fouling Controller
Part No: RXSOL-40-4007-260
Also known as: Scale and Fouling controller in Cooling system 260 Liquid
Organic Anti-Scalant for use in closed cooling water systems , for preventing corrosion and scale Formation in Internal combustion engines, compressor cooling system, DG -set at high or low temperature. It is also acts as a corrosion inhibitor ( Pro
View DetailsOilfield Water Treatment Chemicals
Demulsifier Premium
Part No: RXSOL-16-2064-210
Also known as: Pasetreat 6410, Clarient P 6752, DEMTROL, Separate water in Oil Emusion, Dissolvant Clariant
Can be use as a Separation of emulsified water from crude adsorbent, Sharp interface between crude oil and water.
View DetailsFrequently Asked Questions
How do I order RXSOL Zyme 700 FN?
Quote the product name and part number RXSOL-15-1540-005, quantity, delivery address and required date. Abu Dhabi Chemicals will confirm availability, packaging, price and delivery terms before you order.
How can I request the SDS and TDS for RXSOL Zyme 700 FN?
Use the document request below and include the product name and part number. Ask for the current supplier Safety Data Sheet (SDS), Technical Data Sheet (TDS) and any batch Certificate of Analysis (CoA) required by your procurement team.
How do I confirm suitability for my application?
Check the current product specification against your application, equipment materials and operating conditions. Product grades and formulations differ; use the supplier documentation for the exact product rather than a general category recommendation.